3.64kg/m (19.66Kg per 5.4m length)
AS1720.1
450mm (max). Min. 2 spans
ASTM D570-98
Mean: 1.43%
Max: 1.57%
ASTM G154, or EN 15534-1:2014 Section 8.1 ISO 4892-2:2013, cycle 1
720h, Grey Level= 4-5
ISO 4892-2:2013 cycle 1
After 720-hour test, there was no visual chalking on the surface.
1. AS4586:2013 Oil-wet inclining platform method
Result: R10
2. AS4586-2013 Wet pendulum test method
Result: P5
ISO 16869:2008 Plastic assessment of the effectiveness of fungistatic compounds in plastic formulations
0 (no growth)
ASTM D696-08
3.19x10-5 cm/cm/oC
ASTM D792-13 Method B
1.201g/cm3
BS EN15534-1:2014 + A1: 2017 Section 7.1.2.1 EN15534-4: 2014 Section 4.5.1
Type: Solid profile max/crack length(mm): no crack Max. Residual indentation (mm) 0.08
ASTM D4060-14
Mass/Weight loss, 40.5mg
EU Reach regulation N01907/2006 Article 33(1) Obligation to provide information of safe use.
PASS
All co-extruded composite decking, including Ekodeck+ Designer Series can, under certain conditions, exhibit build-up of static electricity.
Low humidity and dry environmental conditions are the biggest contributing factors of static electricity build-up. Other factors include, but are not limited to, subframe materials, earthing and/or balustrading.
This phenomenon may be reduced by using an anti-static spray (such as ACL Staticide). These products are water based and may require additional applications after rain or other weather conditions. Anti-static mats or insulating touch points such as balustrades or door handles may also assist.
Generally, the static build-up tends to reduce over time as the boards wear in. Ekodeck does not warrant against static build-up in Designer Series boards.
Material Safety Data Sheet
AS ISO 9239.1-2003
Critical flux (transverse): 9.3kW/m2
Critical flux (longitudinal): 5.8kW/m2
Smoke Production: 150%/minute
AS 1530.3:1999
Ignition Time (mins.): 10.8
Flame propagation time (s): 155
Heat release integral (Kj/m2): 683.5