3.64kg/m (19.66Kg per 5.4m length)
AS1720.1
Domestic and residential activities up to 1.8kN = Max. 450mm span (centre to centre)
Non-residential activities up to 2.7kN (but including residential stairs and landings) = Max. 400mm span (centre to centre)
ASTM D570-98
0.63%
ASTM G154, or EN 15534-1:2014 Section 8.1
600h, Grey Level >= 3
ISO 4892-2:2013 cycle 1
After 720-hour test, there was slight colour change. E*=0.58, Grey scale 4-5
1. AS4586:2013 Oil-wet inclining platform method
Result: R10
2. AS4586-2013 Wet pendulum test method
Result: P5
Ekodeck Decking boards are supplied with a certified anti-slip rating as per AS4586:2013. Over time, dependent on traffic, environment and other external factors, the surface may wear. It is the responsibility of the owner to periodically test the boards to ensure anti-slip rating requirements are being met.
Snow Gum | Shadow Grey | Honey Oak | Sand Dune | Redgum | Deep Walnut |
In Dry: 14.33 | In Dry: 8.31 | In Dry: 13.30 | In Dry: 18.29 | In Dry: 9.07 | In Dry: 8.30 |
In Wet: 12.99 | In Wet: 6.14 | In Wet: 10.32 | In Wet: 15.53 | In Wet: 7.38 | In Wet: 6.46 |
ISO 16869:2008 Plastic assessment of the effectiveness of fungistatic compounds in plastic formulations
0 (no growth)
ASTM D696-08
3.19×10-5 cm/cm/oC
ASTM D792-13 Method B
1.19g/cm3
ASTM D2240-05(2010)
D/70/1
ASTM D4812-11
88 J/m
C (Complete break)
BS EN15534-1:2014 + A1: 2017 Section 7.5 EN15534-4: 2014 Section 4.5.7
Brinell hardness: 72 Mpa Rate of elastic recovery: 72%
BS EN15534-1:2014 + A1: 2017 Section 7.1.2.1 EN15534-4: 2014 Section 4.5.1
Type: Solid profile max/crack length(mm): no crack Max. Residual indentation (mm) 0.08
ASTM D4060-14
Mass/Weight loss, 40.5mg
EU Reach regulation N01907/2006 Article 33(1) Obligation to provide information of safe use (see REACH requirement in report for details)
PASS
All co-extruded composite decking, including Ekodeck Flame Fighter can, under certain conditions, exhibit build-up of static electricity.
The biggest contributing factors of static electricity build-up are low humidity and dry environmental conditions, the type of subframe materials used in construction and the presence of earthing and/or metal balustrading. Whilst installations where static is noticeable are rare, Ekodeck is not in control of these factors and does not warrant against static build-up.
This phenomenon may be reduced by using an anti-static spray (such as ACL Staticide). These products are water based and may require additional applications after rain or other weather conditions. Anti-static mats or insulating touch points such as balustrades or door handles with a sealer may provide a more permanent solution. A clear coat can be applied to insulate touch points – for best results use a UV resistant, outdoor-grade coating. Multiple applications may be required to create an effective insulating barrier.
Generally, the static build-up in the boards tends to reduce over time as the boards wear in.
Ekodeck does not warrant against static build-up in Flame Fighter boards due to influencing factors beyond our control.
AS ISO 9239.1-2003
Critical flux (transverse): ≥11kW/m2
Critical flux (longitudinal): 11kW/m2
Smoke Production: 90%/minute
AS 1530.3:1999
Ignition Time (mins.): 11.3
Flame propagation time (s): 150
Heat release integral (Kj/m2): 672.9