Structural Design Certification

Bushfire Rating (BAL)

AS1530.8.1:2018
AS1530.4:2014

Bushfire Attack Level (BAL) – 29

Ekodeck Flame Fighter BAL29 Report

PDF 0.9 MB

Weight

3.64kg/m (19.66Kg per 5.4m length)

Span

AS1720.1

Domestic and residential activities up to 1.8kN = Max. 450mm span (centre to centre)

Non-residential activities up to 2.7kN (but including residential stairs and landings) = Max. 400mm span (centre to centre)

Water Absorption

ASTM D570-98

0.63%

UV Resistance

ASTM G154, or EN 15534-1:2014 Section 8.1

600h, Grey Level >= 3

Weathering test

ISO 4892-2:2013 cycle 1

After 720-hour test, there was slight colour change. E*=0.58, Grey scale 4-5

Slip Resistance

1. AS4586:2013 Oil-wet inclining platform method

Result: R10

Ekodeck Flame Fighter R10 Attar Report 17283 10

PDF 0.5 MB

2. AS4586-2013 Wet pendulum test method

Result: P5

Ekodeck Designer Series P5 Attar Report 17283 9

PDF 0.5 MB

Ekodeck Decking boards are supplied with a certified anti-slip rating as per AS4586:2013. Over time, dependent on traffic, environment and other external factors, the surface may wear. It is the responsibility of the owner to periodically test the boards to ensure anti-slip rating requirements are being met.

Luminance Reflectance Value

AS 1428.1-2009 Appendix B (also compliant with AS/NZS 1428.4.1-2009) Luminance Reflectance Value (LRV) Testing
Snow Gum Shadow Grey Honey Oak Sand Dune Redgum Deep Walnut
In Dry: 14.33 In Dry: 8.31 In Dry: 13.30 In Dry: 18.29 In Dry: 9.07 In Dry: 8.30
In Wet: 12.99 In Wet: 6.14 In Wet: 10.32 In Wet: 15.53 In Wet: 7.38 In Wet: 6.46

Ekodeck LRV Testing Report 2022 AS 1428.1-2009

PDF 0.3 MB

Mould Resistance

ISO 16869:2008 Plastic assessment of the effectiveness of fungistatic compounds in plastic formulations

0 (no growth)

Coefficient of linear thermal expansion

ASTM D696-08

3.19×10-5 cm/cm/oC

Density

ASTM D792-13 Method B

1.19g/cm3

Shore Hardness

ASTM D2240-05(2010)

D/70/1

Izod unnotched impact strength

ASTM D4812-11

88 J/m
C (Complete break)

Resistance to indentation

BS EN15534-1:2014 + A1: 2017 Section 7.5 EN15534-4: 2014 Section 4.5.7

Brinell hardness: 72 Mpa Rate of elastic recovery: 72%

Falling Mass Impact Resistance

BS EN15534-1:2014 + A1: 2017 Section 7.1.2.1 EN15534-4: 2014 Section 4.5.1

Type: Solid profile max/crack length(mm): no crack Max. Residual indentation (mm) 0.08

Abrasion/Wear resistance

ASTM D4060-14

Mass/Weight loss, 40.5mg

Reach

EU Reach regulation N01907/2006 Article 33(1) Obligation to provide information of safe use (see REACH requirement in report for details)

PASS

Toxicity (ROHS: Elementary Analysis and flame retardants)

  1. IEC 62321-5:2013, determination of Cadmium by ICP-OES
    Cadium (Cd): 2
  2. IEC 62321-5:201 3, determination of Lead by ICP-OES.
    Lead (Pb): 14
  3. IEC 62321-4:201 3, determination of Mercury by ICP-OES.
    Mercury (Hg): Not detected
  4. IEC 62321:2008, determination of Hexavalent Chromium by colourimetric method using UV-Vis
    Hexavalent Chromium (CrVI): Not detected
  5. IEC 62321-6:2015, determination of PBBs and PBDEs by GC-MS.
    Sum of PBBs: Not detected

Static Electricity

All co-extruded composite decking, including Ekodeck Flame Fighter can, under certain conditions, exhibit build-up of static electricity.

The biggest contributing factors of static electricity build-up are low humidity and dry environmental conditions, the type of subframe materials used in construction and the presence of earthing and/or metal balustrading. Whilst installations where static is noticeable are rare, Ekodeck is not in control of these factors and does not warrant against static build-up.

This phenomenon may be reduced by using an anti-static spray (such as ACL Staticide). These products are water based and may require additional applications after rain or other weather conditions. Anti-static mats or insulating touch points such as balustrades or door handles with a sealer may provide a more permanent solution. A clear coat can be applied to insulate touch points – for best results use a UV resistant, outdoor-grade coating. Multiple applications may be required to create an effective insulating barrier.

Generally, the static build-up in the boards tends to reduce over time as the boards wear in.

Ekodeck does not warrant against static build-up in Flame Fighter boards due to influencing factors beyond our control.

Ekodeck Designer Series Static Electricity Report

PDF 0.5 MB

Material Safety Data Sheet (MSDS)

Material Safety Data Sheet

Ekodeck Flame Fighter MSDS

PDF 0.1 MB

Burning Characteristics

AS ISO 9239.1-2003

Critical flux (transverse): ≥11kW/m2

Critical flux (longitudinal): 11kW/m2

Smoke Production: 90%/minute

Ekodeck Flame Fighter Burning Characteristics ISO 9239.1

PDF 0.8 MB

AS 1530.3:1999

Ignition Time (mins.): 11.3

Flame propagation time (s): 150

Heat release integral (Kj/m2): 672.9

Ekodeck Flame Fighter Burning Characteristics AS 1530.3

PDF 0.3 MB

Ekodeck Designer Series Leatherwood woman and dog

Get started with Ekodeck

Experience our entire colour range for yourself. We deliver a sample kit complete with each colour direct to your door.

By using this website, you agree to our cookie policy

Accept
ekodeck deck it yourself

Planning to DIY a new deck? Check out our new Deck It Yourself series…

Learn more